AP Chest

February 4th, 2010 by RadiologyTech Leave a reply »

AP Projection Chest

IR size: 14×17 inches

Shielding: Lead shield around waist

Patient Position: Patient is usually supine on cart, if patient is able raise the head of the bed to at least semi-erect position.  Roll patients shoulders forward

Part Position: Place IR behind patient, aligning the top of the IR 1.5 to 2 inches above shoulder.

Central Ray: Center to midsagittal plane at level of T7, Angle the tube to match the long axis of the sternum and ensure the IR is perpendicular to the tube

SID: 72 inches

Collimation: On small patients you can collimate on all four sides

Respiration: Exposure made while patients is holding breath on second full inspiration