-use 8×10 image receptor
-place shield across patient’s lap
-seat patient at end of table with elbow flexed 90 degrees
-pronate hand with fingers extended
-central ray should be directed to proximal interphalangeal (PIP) joint
-collimate on four sides to only show affected finger