Sensitometry Test

February 13th, 2010 by RadiologyTech Leave a reply »

Sensitometry Test

1)      A _______ is a device that measures the amount of blackening on a film.

2)      A _______ is used to produce a uniform optical step wedge on a film.  This is done using light photons, not x-ray photons.

3)      List the five stages of a D log E curve.

4)      The ability to block or stop the transmission of light on a film is called ________.

5)      The optical density range is 0.0 to _______ but diagnostic radiography is best within the range of ________ to ________.

6)      A .3 change in optical density changes your opacity by a factor of 2.  What does it change if you change your optical density by a factor of 1?

7)      T or F: Once D Max is reached it is possible to lose density exposing the film to more radiation?

8)      A ________ relationship exists between silver halide crystal size and film resolution.

9)      The speed point of a film is where and OD value of ______ + base + fog is achieved.

10)   Film speed and the thickness of the emulsion layer are _______ related.

11)   Latitude and Contrast are _______ related.

12)   ________ is the primary characteristic of film that deals with how accurate the image recorded and is measured with line pairs.

13)   The contrast is determined by the slope of a straight line portion.  The slope of any point on the straight line can be measured, these points are called ________ points.

 

 

 

 

Answers

1)      Densitometer

2)      Sensitometer

3)      B + F, Toe, Straight line, Shoulder, D Max

4)      Opactiy

5)      4, .5-1.5

6)      By a factor of 10

7)      True

8)      Inverse

9)      1.0

10)   Directly

11)   Inversely

12)   Resolution

13)   Gradient